Proudly American ยท Family-Owned & Operated

Your Tampa Fireplace TeamCall (833) 435-4697

(833) 435-4697 Book Online

Insulated chimney liners installed in Bloomingdale

Cracked tiles, no lining at all or a new appliance? Our local team plans the chimney liner your Bloomingdale home needs.

  • Family owned and operated
  • Same-day service available
  • No hidden fees
  • Workmanship warranty
Contents

Chimney Services

Chimney Liner Installation From a Local Family Team

Relining booked within 72 hours of the free flue check is 10% off. This is how our specialists plan the job.

Fitting a round liner into a narrow flue

Some chimneys have a flue too tight for a round liner of the required size. Flexible liners can be ovalized to fit, and the manufacturer notes that this reduces their cross-sectional area.

An ovalized liner therefore has to be checked against the sizing rule after shaping. A liner that fits the gap but falls below the required area has only moved the problem.

If your flue is tight, we tell you what shape and size will work and what the reshaping does to the numbers.

Relining a chimney with a bend in the flue

Many flues change direction on their way up. The Florida Building Code limits how far a masonry chimney may offset, and clay liners may slope no more than 30 degrees from vertical.

Flexible liners are made for that kind of route, and the instructions allow extra length for each offset. In tight bends, installers guide the liner down with a rope and a cone instead of forcing it.

Our crew checks the path of the flue before ordering, so the liner arrives long enough and the installation does not damage it.

Liners for gas appliances follow their own code path

Gas appliances sit on a separate code path. Florida's residential code sends their flue lining to the fuel gas chapter instead of the general masonry rules. The appliance listing sets the vent type and size.

Liner instructions note that liners serving gas appliances do not require insulation between the liner and the masonry, although performance improves with it. A flue that once served wood may be the wrong size for a gas appliance, so the existing flue is never assumed to suit it.

If your chimney serves a gas appliance, we read its venting instructions first and explain how the liner fits them.

Older chimneys built without a lining

Some older chimneys were built with no flue lining at all. BIA's historical chimney guidance shows that an unlined chimney called for an 8-inch nominal wall, twice the thickness of a lined one.

Today the Florida Building Code requires masonry chimneys to be lined. An unlined flue is therefore a question to settle before the fireplace is used again. Relining is often the simplest way to bring such a chimney up to that requirement without rebuilding it.

We check how your chimney was built and explain the lining options that fit its size and condition.

On any service we offer

Free flue check first, then 72 hours to book the relining at 10% off.

Book Online

What's Included

The Liner Work Proposed for Bloomingdale

  1. Condition of the existing flue lining along its length
  2. Chimney height above the roof and nearby structures
  3. Removal of old liner pieces and debris
  4. Roof and room protection during installation

Proudly American

A clear scope, an agreed price and workmanship we stand behind.

Call (833) 435-4697

Replace That Failing Chimney Liner

Describe the fireplace or appliance on the chimney, and our relining crew will look up the flue in Bloomingdale at no cost.

Request a free inspection for your Tampa home. We will call to arrange the visit.

Call (833) 435-4697