Checking the switch side of the circuit

On a millivolt system, the wall switch, remote receiver or thermostat closes the circuit that tells the valve to open the main burner. The service manual includes a test for this, jumping the switch terminals at the valve for a moment, which shows whether the fault sits in the control or in the valve itself.

Corroded terminals, loose wire nuts and long runs of thin wire can drop enough voltage to leave the burner dark while the pilot keeps burning. Our pros clean, tighten or replace the control wiring as the test shows, and the jumper never stays in place after testing.

Relighting after a propane tank runs dry

When a propane tank runs out, the pilot goes out with it. The model fuel gas code has the piping leak-checked right after gas service comes back from an interruption, and the fireplace is relit only once that check is done.

Propane is heavier than air and settles low, which is why lighting instructions ask you to smell near the floor before relighting. If you smell gas, leave the house and call your gas supplier or 911 once you are outside. Otherwise, our pros can relight and test the fireplace after a delivery.

Vent faults that put the flame out

A pilot and burner that both go out while the fireplace is running can trace back to the vent. One service manual lists a leaking inner vent pipe, the pitch of a horizontal run and the way the termination cap was installed among the causes to check.

Our pros inspect the vent path they can reach and tell you when the fault calls for vent repair, which we quote on its own line. A new burner part cannot fix exhaust that is mixing with the intake air.

Leaving factory valve settings alone

Gas valves leave the factory set for the model they serve, and the installation manual tells installers not to change those settings. Turning up a regulator to get a bigger flame can overfire the burner and damage the valve.

When a flame looks small, our specialists look for the real cause, such as supply pressure, a partly blocked orifice or logs out of place. The valve settings stay where the maker put them, and your estimate explains what we found.

On any service we offer

In Egypt Lake-Leto, gas fireplace service booked within 72 hours of the visit is 10% off.

Book Online

Free Inspection

Everything Tested Before a Part Is Ordered

  1. Pilot flame shape and how it wraps the sensors
  2. Inlet and manifold pressure at the valve
  3. Remote, receiver and batteries
  4. Draft and spill switch on natural-vent units